Part 1 – General – VB350
16 mil
1.1 Section Includes
A. Products
supplied under this section
1. Vapor
Barrier and seam tape for installation under
concrete slab
1.2
Related Section
A. Section
07260 – Under Slab Vapor Retarder
B. Section
03300 – Cast-in-place Structural Concrete
1.3
References
A. American
Concrete Institute (ACI)
1. ACI
302.1 R – 96 – Vapor retarder / barrier
membrane is greater than or equal to 10 mils
in thickness
B. American
Society for Testing and Materials (ASTM)
1. ASTM
E 96 – Water vapor transmission of materials
2. ASTM
E 1745 – Water vapor retarder used in
contact with soil or granular fill under
concrete slabs
3. ASTM
E 154 – Water vapor retarder used in contact
with earth under concrete slabs, walls, or
ground cover
4. ASTM
E 1643 – Installation of water vapor
retarder used in contact with earth under
concrete slabs
1.4
Submittals
A. Submit
manufacturers product data and installation
instruction
B. Submit
laboratory test results showing compliance
with ACI and ASTM standards
C. Submit
manufacturers product samples
Part 2 – Products – VB350
16 mil.
2.1 Manufacturer
A. Barrier-Bac, 9 Peach Tree Hill Road,
Livingston, NJ 07039,
973-994-8035 * Fax: 973-740-8244
2.2 Materials
A. High density polyethylene vapor barrier
1.
Description: Three layer coextruded
biaxially oriented polyethylene membrane
2. Water
vapor transmission ASTM E – 96 less than or
equal to 0.007 g / m2
*h
3. Tensile
strength ASTM D – 882 minimum 63 lbs / in
4. Permeance
ASTM E – 96 less than or equal to .009 perms
5. Puncture
resistance ASTM D – 1709 greater than or
equal
to 2226 grams
2.3 Accessories
A.
Seam tape
1. 8 mil PVC tape with rubber/resin
adhesive. Tensile strength not
less than 22 lbs./inch minimum per ASTM D
882.
Minimum
width 4 inches.
B. Pipe
Boots
1. Follow manufacturers instruction to
construct pipe boots with
vapor barrier membrane and seam tape